Sample 80% Gold
Sample ID SD240209-006 (76160) Matrix Concentrate (Inhalable Cannabis Good)
Tested for MCNB Holding Corporation
Sampled - Received Feb 08, 2024 Reported Feb 10, 2024
Analyses executed CAN+
CAN+ - Cannabinoids Analysis
Analyzed Feb 10, 2024 | Instrument HPLC-VWD | Method SOP-001
The expanded Uncertainty of the Cannabinoid analysis is approximately ±7.806% at the 95% Confidence Level
LOQ
LOD
Analyte mg/g mg/g Result Result
mg/g
%
Cannabidivarin (CBDV) 0.039 0.16 1.35 13.52
Cannabidiolic Acid (CBDA) 0.001 0.16 ND ND
Cannabigerol Acid (CBGA) 0.001 0.16 ND ND
Cannabigerol (CBG) 0.001 0.16 1.89 18.92
Cannabidiol (CBD) 0.001 0.16 72.98 729.83
Tetrahydrocannabivarin (THCV) 0.001 0.16 0.32 3.18
Cannabinol (CBN) 0.001 0.16 1.44 14.42
Tetrahydrocannabinol (Δ9-THC) 0.003 0.16 4.25 42.53
Δ8-tetrahydrocannabinol (Δ8-THC) 0.004 0.16 ND ND
Cannabicyclol (CBL) 0.002 0.16 ND ND
Cannabichromene (CBC) 0.002 0.16 1.33 13.34
Tetrahydrocannabinolic Acid (THCA) 0.001 0.16 ND ND
Total THC ( THCa * 0.877 + Δ9THC ) 4.25 42.53
Total THC + Δ8THC ( THCa * 0.877 + Δ9THC + Δ8THC ) 4.25 42.53
Total CBD ( CBDa * 0.877 + CBD ) 72.98 729.83
Total CBG ( CBGa * 0.877 + CBG ) 1.89 18.92
Total Cannabinoids Analyzed 83.57 835.74
UI Unidentified Authorized Signature
ND Not Detected
N/A Not Applicable
NT Not Reported Acc. #85368
LOD Limit of Detection
LOQ Limit of Quantification
<LOQ Detected
>ULOL Above upper limit of linearity Scan the QR code to verify authenticity.
CFU/g Colony Forming Units per 1 gram Brandon Starr, Lab Manager
TNTC Too Numerous to Count Sat, 10 Feb 2024 11:46:05 -0800
PharmLabs San Diego | 3421 Hancock St, Second Floor, San Diego, CA 92110 | 619.356.0898 | ISO/IEC 17025:2017 Acc. L17-427-1
*This report shall not be reproduced except in full, without the written approval of the lab. This report is for informational purposes only and should not be used to diagnose, treat or prevent any disease. Results are only for samples and batches indicated. Results are reported on
an "as received" basis, unless indicated otherwise. When a Pass/Fail status is reported, that status is intended to be in accordance with federal, state and local laws which are required for the customer to be in compliance. The measurement of uncertainty is not included in the
Pass/Fail evaluation unless explicitly required by federal, state or local laws and has been reported on the certificate of analysis. Measurement of uncertainty is available upon request.